grounded and mount a grounding kit on top of the foil. For<br />

details on the jumper cable see Jumper cable for grounding<br />

on page F-14.<br />

Jumper cable<br />

F.2.2<br />

Cable to ADU<br />

Figure F-1: Extending the ground plane<br />

Grounding the ADU<br />

You can ground the ADU to the ship/hull via one or more of its<br />

mounting bolts. Make sure to remove painting, dirt, grease<br />

etc. at the mounting holes in order to make good electrical<br />

contact to the hull. Use serrated washers when securing the<br />

mounting bolts and seal the joint with protective coating to<br />

avoid corrosion.<br />

Grounding Recommendations<br />

FFFF<br />

Grounding and RF<br />

Antenna bottom<br />

Serrated washer<br />

(stainless steel)<br />

M12 bolt<br />

(stainless steel)<br />

Mounting base<br />

Figure F-2: Grounding the ADU<br />

Note<br />

For optimum grounding use the mounting bolt located closest to the ADU<br />

cable plate, see Figure 3-22: ADU, bolt for optimum grounding on page 3-22.<br />

98-133966-E2 Appendix F: Grounding and RF protection F-3