5.2.3 Power cable recommendations<br />

5.2.3.1 Overview<br />

Figure 5-1: Measuring the ship source impedance<br />

The ACU is delivered with a power connector (PCB plug-in<br />

connector, female plug, Weidmuller, Part number 1930050000),<br />

which accepts wires up to AWG10/6 mm 2 .<br />

• When installing the power cable, install positive and negative<br />

supply wires closely together side by side to keep cable<br />

inductance low.<br />

• Ensure that cable inductance for the selected cable at the desired<br />

length is less than 50 uH. Approximately 50 m maximum length.<br />

Power cable selection<br />

5555<br />

Connecting power<br />

5.2.3.2 Calculating the maximum power cable length<br />

For 24 VDC operation, the total impedance must be max. 60 mOhm<br />

(R max ), including the source impedance in the ship installation<br />

(R source ).<br />

The total impedance is made up of the following:<br />

• Source impedance in the ship installation<br />

• Impedance of the selected power cable<br />

To calculate the maximum cable extension, do as follows:<br />

1. First measure the source impedance in the ship installation as<br />

shown in Measuring the ship source impedance on page 5-2.<br />

2. Find the resistance per meter (Rwire) for the cable type you are<br />

going to use.<br />

For 4 mm 2 /AWG 11, the value is 4.8 mOhm/m at 55°C<br />

For 6 mm 2 /AWG 10, the value is 3.8 mOhm/m at 55°C<br />

98-133966-E2 Chapter 5: Connecting power 5-3