Grounding Recommendations<br />

F.2 Grounding Recommendations<br />

F.2.1<br />

Grounding the ACU<br />

The ACU should be grounded to the ship/hull. For this purpose you<br />

may use a short ADU cable and a grounding kit. Further, the ACU<br />

must be grounded at its grounding stud in order to ensure proper<br />

grounding if the short ADU cable is disconnected. For further<br />

information, see Grounding the terminal on page 2-33.<br />

If you use the Extended cable support, make the ground<br />

connections through the cable support. You may need to extend the<br />

ground plane using copper foil, see the following section.<br />

F.2.1.1<br />

Extending the ground plane<br />

In some cases it may not be possible to access the hull and at the<br />

same time place the ACU in a suitable place. A way to insure good<br />

grounding and at the same time make it possible to ground the coax<br />

cable - is to extend the ship ground plane by means of copper foil.<br />

The maximum length of the foil is determined by the width of the<br />

foil:<br />

Copper foil 5 cm wide: Max 50 cm<br />

Copper foil 10 cm wide: Max 100 cm<br />

Copper foil 20 cm wide: Max 200 cm<br />

Note<br />

The foil must be at least 0.1 mm thick.<br />

Connect the foil to the hull by plenty of screws or hard–soldering.<br />

Run the foil past the place where the short ADU cable is to be<br />

F-2 Appendix F: Grounding and RF protection 98-133966-E2