Site preparation<br />

3.2.6 ADU mast design: Foundation and height<br />

The ADU mast must be designed to carry the weight of the ADU unit,<br />

which is 135 kg (+ the weight of the mast flange). The mast must<br />

also be able to withstand on-board vibrations and wind speeds up<br />

to 110 knots on the radome, even in icing conditions.<br />

3.2.6.1 ADU mast flange<br />

Fit the top of the ADU mast with a flange with clearance holes<br />

matching the bushings in the radome and with minimum 4 gusset<br />

plates. No center hole is necessary in the flange.<br />

• Flange thickness: Minimum 15 mm.<br />

• 4 gusset plates: Minimum 15 mm thick, must be placed close<br />

to the holes in the mounting plate and evenly distributed.<br />

Gusset plates<br />

(15 mm thick) 15 mm<br />

Figure 3-6: ADU mast flange, top and side view<br />

Recommended flatness on the mast mount plateau is below 3,0 mm.<br />

Figure 3-7: ADU mast flange, recommended flatness on the mast mount plateau<br />