Alternative grounding for fibre glass hulls<br />

F.5.2<br />

Grounding the ADU<br />

If the mounting base of the ADU is electrically connected to any<br />

other ground potential than the ACU (e.g. Lightning Ground), the<br />

ADU must be isolated at its mounting bolts by means of shoulder<br />

bushings and washers - see section F.6.3.<br />

However, a ground connection must be established via one of the<br />

mounting bolts using a separate ground cable. The ground cable<br />

must be routed parallel and in close proximity to the shielded coax<br />

cable hence connecting the ADU to the ACU Grounding kit. A heavy<br />

gauge wire with tinned strands (min. 6 mm 2 ) can be used for this<br />

purpose.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Figure F-5: Alternative grounding for fibreglass hulls<br />

F-10 Appendix F: Grounding and RF protection 98-133966-E2