List of ACU events<br />

Error code (ID) ACU PCB Severity Description Explanation<br />

0806D-0 ADM ERROR ADU power The ADU supply voltage is outside the<br />

allowed limits. This could happen if the<br />

PSM fails to provide the requested<br />

supply voltage or if the voltage<br />

difference across the hotswap is<br />

unacceptable high.<br />

0806E-0 ADM ERROR VMU 10 MHz reference The VMU 10 MHz Rx or Tx reference<br />

signal is not present. Whether this error<br />

Rx or Tx reference, depends on the users<br />

selection on the modem profile page.<br />

Make sure VMU Rx/Tx cable is<br />

connected and that the VMU is<br />

configured to output the RX/TX 10 MHz<br />

reference signal.<br />

0806F-0 ADM ERROR ROSS synchronization The ACU has become out of sync with<br />

the ROSS device, most likely because the<br />

ACU has been replaced, or the ROSS<br />

satellite profile is new. A manual<br />

(forced) hand off sequence must be<br />

initiated from the ROSS, refer to the<br />

ROSS manual for the procedure.<br />

08073-0 ADM WARNING Slave connection The system is configured as a dual<br />

antenna master, but no dual mode slave<br />

has connected to it. Either disable dual<br />

mode from the web mmi or configure a<br />

another system as a dual mode slave.<br />

08074-0 ADM WARNING Master connection The system is configured as a dual<br />

antenna slave, but it was not possible to<br />

connect to the dual mode master. Check<br />

that the IP address entered in the<br />

modem profile is correct and check that<br />

the master and slave systems are<br />

physically connected as described in the<br />

manual.<br />

08076-0 ADM WARNING Incompatible message version The system is configured as a dual<br />

antenna system, but the software<br />

versions on master and slave system are<br />

different. Ensure that both master and<br />

slave has identical software.<br />

Table G-2: ACU event messages (Continued)<br />

G-10 Appendix G: System messages 98-133966-E2