9.6 Updating VIM/PCM calibration<br />

data<br />

After installing a new VIM (VSAT Interface Module) or PCM<br />

(Pedestal Control Module) you must update the calibration data.<br />

The ACU does not know which of the two modules (PCM or VIM) has<br />

been replaced. The ACU needs to know which set of data to keep.<br />

You must select the module that was not exchanged so the<br />

calibration data can be copied to the module that was exchanged<br />

during service.<br />

1. Enter the web interface (http://192.168.0.1) and click SERVICE ><br />

XIM DATA. A screen similar to the one in the figure below will<br />

appear:<br />

2. The figure shows at Unit-no Unit-Serial-Number for the PCM,<br />

because this module was exchanged during service. In this case<br />

the user must press the select button below the VIM module in<br />

order to copy the current calibration data to the new PCM<br />

module.<br />

Important<br />

Figure 9-120: Updating VIM/PCM calibration data (example)<br />

Select always the XIM data for the module that<br />

was not exchanged.<br />

3. Click Select, then a warning will appear.<br />

Figure 9-121: XIM data, warning<br />

4. Click OK to continue, the data is copied into the replaced module.<br />

Updating VIM/PCM calibration data<br />