12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 118Opti<strong>on</strong>s Software versi<strong>on</strong> 2tensi<strong>on</strong> setting. If TIA CCD is present <strong>on</strong> a system with Gatan cameras, the software will also requirethat TIA is running (otherwise the TIA CCD magnificati<strong>on</strong> table will not be set).The Start butt<strong>on</strong> will change to a yellow color and its capti<strong>on</strong> toStop. Pressing the Start butt<strong>on</strong> when it is yellow will stop thecalibrati<strong>on</strong> procedure.Starting the calibrati<strong>on</strong> procedure will open a log in a separate window. The log shows what is beingd<strong>on</strong>e and what the results are. It can be saved in text format (under the File menu of the log window).The log can also be printed (if a printer is available to the system). Text files can also be opened in thelog file window.Next butt<strong>on</strong>During the calibrati<strong>on</strong> procedure the operator will be expected to do certain things as setting upilluminati<strong>on</strong>, specimen area and focus, as well as change specimen (later in the procedure). Once thesethings have been d<strong>on</strong>e (as given by the instructi<strong>on</strong>s displayed), pressing the Next butt<strong>on</strong> will c<strong>on</strong>tinuewith the procedure.Flap-out butt<strong>on</strong>The flap-out butt<strong>on</strong> leads to the Report, File and Opti<strong>on</strong>s tabs of the Automated Experiments C<strong>on</strong>trolPanel.9.1.1 The HM magnificati<strong>on</strong> calibrati<strong>on</strong> procedureThe calibrati<strong>on</strong>s procedure c<strong>on</strong>sists of a calibrati<strong>on</strong> for each magnificati<strong>on</strong> of the series. The followingprocedure is used:• Direct cross-grating calibrati<strong>on</strong> of the lowermost SA magnificati<strong>on</strong>.• Calibrati<strong>on</strong> of the image shift at the lowermost SA magnificati<strong>on</strong> (this does not calibrate amagnificati<strong>on</strong>, but the image shift itself, used later).• Calibrati<strong>on</strong> of the Mi magnificati<strong>on</strong>s with the cross-grating method.• Calibrati<strong>on</strong> of the remaining SA magnificati<strong>on</strong>s, going up in magnificati<strong>on</strong>. The software detects themagnificati<strong>on</strong> at which the cross-grating method does not work anymore and displays a warning inthat sense. Then the software automatically switches to the image shift method. Once themagnificati<strong>on</strong> is high enough for high-resoluti<strong>on</strong> images (determined from the measured pixel size),the software will switch to the lattice-image method.• Calibrati<strong>on</strong> of the Mh magnificati<strong>on</strong>s with the lattice-image method.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!