12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 135Opti<strong>on</strong>s Software versi<strong>on</strong> 2High tensi<strong>on</strong>Pressing the High tensi<strong>on</strong> butt<strong>on</strong> switches the high tensi<strong>on</strong> <strong>on</strong> and off. The color of the butt<strong>on</strong> indicatesthe high-tensi<strong>on</strong> status (yellow = <strong>on</strong>). The high-tensi<strong>on</strong> setting is the <strong>on</strong>e shown in the drop-down list box<strong>on</strong> the right. The High tensi<strong>on</strong> butt<strong>on</strong> has three possible settings:• The high tensi<strong>on</strong> is enabled but off : the butt<strong>on</strong> is 'normal' gray.• The high tensi<strong>on</strong> is <strong>on</strong> : the butt<strong>on</strong> is yellow.• The high tensi<strong>on</strong> is disabled : the text in the butt<strong>on</strong> is gray.The high tensi<strong>on</strong> is enabled through the High tensi<strong>on</strong> enable butt<strong>on</strong> <strong>on</strong> the System On/Off Panel.High-tensi<strong>on</strong> selecti<strong>on</strong>The high tensi<strong>on</strong> setting is by clicking in the drop-down list box and selecting the required setting (arange of fixed settings, comprising :• 40, 60, 80 and 100 kV for <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 10• 20, 40, 60, 80, 100 and 120 kV for <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 12• 20, 40, 80, 120, 160 and 200 kV for <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 20• 50,100,150,200, 250 and 300 kV for <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> 30FilamentThe Filament butt<strong>on</strong> switches the filament <strong>on</strong> or off. The color of the butt<strong>on</strong> indicates the filament status(yellow = <strong>on</strong>). The butt<strong>on</strong> is <strong>on</strong>ly enabled when the high tensi<strong>on</strong> is <strong>on</strong>.SaturateThe Saturate butt<strong>on</strong> starts or stops the filament autosaturati<strong>on</strong> procedure. The color of the butt<strong>on</strong>indicates whether the procedure is active or not (yellow = active). The butt<strong>on</strong> is <strong>on</strong>ly enabled when thehigh tensi<strong>on</strong> is <strong>on</strong>.Current filament settingThe value gives the currently active filament setting (corresp<strong>on</strong>ding to the value displayed underneaththe progress bar).User filament settingThe User filament index is set with the spin c<strong>on</strong>trol. Spin the value to the required setting. The valuecannot exceed the filament limit set by the Supervisor. When the Enter butt<strong>on</strong> is enabled (which occursafter the value has been changed by the user), the value currently displayed can be sent to the server bypressing the butt<strong>on</strong> (as l<strong>on</strong>g as the butt<strong>on</strong> is enabled, the server has not been updated).Filament setting displayThe Filament setting display shows the currently active setting of the filament. The value is displayed innumerical format underneath as well as in a progress bar. The progress bar always has a range from 0to a value that is a multiple of ten equal to or above the filament limit,. The filament limit is shown by ared bar coming from the right.Emissi<strong>on</strong> currentThe emissi<strong>on</strong> current display shows the value of the emissi<strong>on</strong> current.Emissi<strong>on</strong> settingThe emissi<strong>on</strong> setting can be changed with the spin c<strong>on</strong>trol within the range 1 to 6.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!