12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 121Opti<strong>on</strong>s Software versi<strong>on</strong> 2The following procedure is used:• Direct cross-grating calibrati<strong>on</strong> of a lower HM-STEM magnificati<strong>on</strong> (not necessarily the lowermostbecause this may be too low to resolve the grating squares effectively). If the image distorti<strong>on</strong> is toohigh, the software will automatically adjust the distorti<strong>on</strong>s in an iterative procedure until the distorti<strong>on</strong>sare less than 0.1% (vector lengths of the grating square dimensi<strong>on</strong>s) and 0.1° (angle betweenvectors).• Direct cross-grating calibrati<strong>on</strong> of a comparable Microprobe STEM magnificati<strong>on</strong>. If the imagedistorti<strong>on</strong> is too high, <strong>on</strong>ce again the software will automatically adjust the distorti<strong>on</strong>s in an iterativeprocedure until the distorti<strong>on</strong>s are less than 0.1% (vector lengths of the grating square dimensi<strong>on</strong>s)and 0.1° (angle between vectors).These STEM calibrati<strong>on</strong> procedure will be run for a total STEM rotati<strong>on</strong> angle of 0°. This means that thefree (user) STEM rotati<strong>on</strong> is set to 0°, and the aligned value (which corrects for the mismatch betweenstage axes and STEM image axes) is also temporarily set to 0° (the latter value is reset at the end of theprocedure to the starting value). Effectively this means that the smallest distorti<strong>on</strong>s and most accuratemagnificati<strong>on</strong>s are achieved at the same STEM rotati<strong>on</strong> angle.Note: Both types of STEM-mode magnificati<strong>on</strong>s are str<strong>on</strong>gly dependent <strong>on</strong> the pivot points,perpendicular correcti<strong>on</strong>s and distorti<strong>on</strong> adjustment. For STEM magnificati<strong>on</strong>s as accurate as possible,the same STEM settings should be used as during the calibrati<strong>on</strong>. It is therefore advised to adjust thepivot points and perpendicular correcti<strong>on</strong>s carefully before the calibrati<strong>on</strong> and store these settings in analignment file (after the calibrati<strong>on</strong>, because that may have included adjustment of the STEM distorti<strong>on</strong>)and having users always use those alignments. If the STEM distorti<strong>on</strong>s initially were a l<strong>on</strong>g way off, stopthe procedure after the distorti<strong>on</strong> adjustment and check the pivot points and perpendicular correcti<strong>on</strong>s,and then restart the procedure.The Microprobe STEM magnificati<strong>on</strong> calibrati<strong>on</strong> does not result in a calibrati<strong>on</strong> file. The calibrati<strong>on</strong> valuefor the Microprobe STEM magnificati<strong>on</strong> is directly set to the <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> software and also entered as acalibrati<strong>on</strong> value in the system branch of the microscope settings in the registry.9.1.7 Measurement <strong>on</strong> cross-gratingThe magnificati<strong>on</strong> calibrati<strong>on</strong> is d<strong>on</strong>e <strong>on</strong> the basis of a standard specimen, a cross-grating. Thisspecimen has squares <strong>on</strong> it with a spacing of 463 nm. The software will acquire an image of the crossgratingand analyse that to find the basic spacing. The analysis is d<strong>on</strong>e either using an auto-correlati<strong>on</strong>or an FFT (at high and low magnificati<strong>on</strong>s, respectively) in which the two basic vectors will be out<strong>line</strong>d bycircles. Additi<strong>on</strong>al circles may be present further away from the center to show the positi<strong>on</strong> of themultiple of the base vector that is actually used for further refinement of the measurement.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!