12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 132Opti<strong>on</strong>s Software versi<strong>on</strong> 210 TEM AutoGun (FP5460/20)10.1 AutoGun proceduresThe AutoGun C<strong>on</strong>trol Panel provides a number of automated procedures. A short descripti<strong>on</strong> of theseprocedures is given below.10.1.1 Auto C<strong>on</strong>dit<strong>on</strong>ingC<strong>on</strong>diti<strong>on</strong>ing can be used to stabilize the high tensi<strong>on</strong>. It is mostly used after an exchange of a filamentor <strong>on</strong> higher-voltage (200kV or higher) instruments. C<strong>on</strong>diti<strong>on</strong>ing takes the high tensi<strong>on</strong> up in c<strong>on</strong>trolledsteps while m<strong>on</strong>itoring the vacuum pressure in the gun. If the pressure remains more than 2 log stepsabove the previous attained level, the procedure will wait for it to drop again. If the pressure exceeds thepreviously attained value by a large amount, the procedure will step the high tensi<strong>on</strong> back a bit and wait.C<strong>on</strong>diti<strong>on</strong>ing goes up to the specified level with the delay step, both as defined by the user.On 100 and 120kV c<strong>on</strong>diti<strong>on</strong>ing takes place by slowly increasing the high tensi<strong>on</strong> up to the maximum ofthe instrument (these microscopes do not have the ability to increase the high tensi<strong>on</strong> bey<strong>on</strong>d thehighest value). Once the user-defined goal has been reached, the c<strong>on</strong>diti<strong>on</strong>ing procedure is finished. Ifthe currently active high-tensi<strong>on</strong> setting is not <strong>on</strong>e of the fixed high-tensi<strong>on</strong> steps, the high tensi<strong>on</strong> will beset to the closest fixed high-tensi<strong>on</strong> step below the current value.On 200 and 300kV instruments, the c<strong>on</strong>diti<strong>on</strong>ing will take place in the normal regime at low high tensi<strong>on</strong>settings, but switch to true c<strong>on</strong>diti<strong>on</strong>ing when an overvoltage (a high tensi<strong>on</strong> value bey<strong>on</strong>d the normalmaximum of 200 or 300kV) is required. After the user-define goal has been reached, the procedure willkeep the high tensi<strong>on</strong> at that value for 10 more minutes for stabilizati<strong>on</strong>. Afterwards the high tensi<strong>on</strong> isset to the closest fixed high-tensi<strong>on</strong> step equal to or below the current value.The starting point for the c<strong>on</strong>diti<strong>on</strong>ing depends <strong>on</strong> the current high-tensi<strong>on</strong> status :• If the high tensi<strong>on</strong> is off, it will be changed to lowermost fixed high-tensi<strong>on</strong> step.• If the high tensi<strong>on</strong> is <strong>on</strong>, the current high tensi<strong>on</strong> value defines the starting point.During c<strong>on</strong>diti<strong>on</strong>ing the c<strong>on</strong>trol panel displays how much time c<strong>on</strong>diti<strong>on</strong>ing is estimated to take. Theestimate is based <strong>on</strong> the assumpti<strong>on</strong> that there will be no delays due to vacuum pressures increases.C<strong>on</strong>diti<strong>on</strong>ing is accessible <strong>on</strong>ly to Expert user level or higher.10.1.2 Auto Saturati<strong>on</strong>The saturati<strong>on</strong> of thermi<strong>on</strong>ic filaments is often problematic. Many microscope users tend to try andremove all structure visible in the focused beam (while especially LaB6 filaments tend to have a structurethat cannot be removed or <strong>on</strong>ly by str<strong>on</strong>gly oversaturating the filament). The resulting overheating leadsto c<strong>on</strong>siderable reducti<strong>on</strong>s in filament life time. The correct saturati<strong>on</strong> point of a filament is the pointwhere further increases in heating current do not lead to significant increases in beam current. Once thebeam is defocused for normal operati<strong>on</strong>, any structure visible in the focused beam disappears.The AutoGun software has a procedure for automatically saturating the filament to the correct point. Thefinal measurement is always made using the screen current as a functi<strong>on</strong> of filament step, combined withrefinement of the gun tilt. The typical pattern seen is an S-shaped curve when the filament setting is

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!