12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 157Opti<strong>on</strong>s Software versi<strong>on</strong> 2The following calibrati<strong>on</strong> procedures are used :• Magnificati<strong>on</strong> calibrati<strong>on</strong>• Image-shift calibrati<strong>on</strong>• Stage calibrati<strong>on</strong>• Stigmator alignment• Focus/stigmator calibrati<strong>on</strong>Magnificati<strong>on</strong> calibrati<strong>on</strong>The software will acquire an image of the cross-grating and analyse that to find the basic spacing. Theanalysis is d<strong>on</strong>e using an auto-correlati<strong>on</strong> (at high magnificati<strong>on</strong>s) or an FFT (at low magnificati<strong>on</strong>s) inwhich the two basic vectors will be out<strong>line</strong>d by circles.An image of a cross-grating, showing the 463 nm squares.The result of the magnificati<strong>on</strong> calibrati<strong>on</strong>. The autocorrelati<strong>on</strong>of the cross-grating image (zoomed in 2x) shows the centralpeak pointed at by the <strong>line</strong> (which has been added <strong>manual</strong>ly forclarity). The software adds the two circles around the two basevectors of the pattern. It is important that these circles arelocated at the correct positi<strong>on</strong>s and not e.g. at the diag<strong>on</strong>als ofthe squares. Additi<strong>on</strong>al circles are placed at the multiples of thebase vectors used to show how many base vectors were usedtogether for the analysis.Image-shift calibrati<strong>on</strong>The image-shift calibrati<strong>on</strong> procedure performs a calibrati<strong>on</strong> of the image shift <strong>on</strong> the CCD. Thiscalibrati<strong>on</strong> must be d<strong>on</strong>e for all magnificati<strong>on</strong>s in the required range (up to magnificati<strong>on</strong>s of ~150kx).Normally the whole range is calibrated in <strong>on</strong>e procedure, but it also possible to (re)calibrate the imageshift for an individual magnificati<strong>on</strong> (e.g. when it appears that the calibrati<strong>on</strong> in the complete procedurewent wr<strong>on</strong>g for <strong>on</strong>e magnificati<strong>on</strong>, that magnificati<strong>on</strong> can be red<strong>on</strong>e later).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!