12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 148Opti<strong>on</strong>s Software versi<strong>on</strong> 210.11 AutoGun C<strong>on</strong>trol (Expert) – (FEG)The AutoGun C<strong>on</strong>trol Panel provides access to the extracti<strong>on</strong>limit as well as the C<strong>on</strong>diti<strong>on</strong>ing procedure.Extracti<strong>on</strong> limitThe filament limit is the value up to which the filament setting can be increased before it stopsautomatically. The value can be adjusted by Expert user and Supervisor.C<strong>on</strong>diti<strong>on</strong> statusIt is not always possible to start the c<strong>on</strong>diti<strong>on</strong>ing procedure. The C<strong>on</strong>diti<strong>on</strong> status indicates whyc<strong>on</strong>diti<strong>on</strong>ing is not possible (apart from another procedure currently running). If c<strong>on</strong>diti<strong>on</strong>ing is possible,the c<strong>on</strong>diti<strong>on</strong> status is not visible and the C<strong>on</strong>diti<strong>on</strong> butt<strong>on</strong> is enabled.C<strong>on</strong>diti<strong>on</strong>Pressing the C<strong>on</strong>diti<strong>on</strong> butt<strong>on</strong> starts or stops the C<strong>on</strong>diti<strong>on</strong>ing procedure. The color of the butt<strong>on</strong>indicates the status (yellow = active).C<strong>on</strong>diti<strong>on</strong> toThe value for c<strong>on</strong>diti<strong>on</strong> to is the goal used by the c<strong>on</strong>diti<strong>on</strong>ing procedure. For Experts the suggestedvalue is the maximum high tensi<strong>on</strong> plus 5% if an overvoltage is possible (200 and 300kV), otherwise it isthe maximum high tensi<strong>on</strong>.C<strong>on</strong>diti<strong>on</strong> delay stepThe c<strong>on</strong>diti<strong>on</strong> delay step defines the number of sec<strong>on</strong>ds the c<strong>on</strong>diti<strong>on</strong>ing procedure will before it takesanother step (subject to the vacuum pressure being low enough).Operate and standby hoursThe FEG Timers c<strong>on</strong>trol panel displays the date the timers were started (FEG tip installati<strong>on</strong>) and thehours the FEG tip has run in Standby and Operate modes. The timers can be reset <strong>on</strong>ly by service.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!