12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 96Opti<strong>on</strong>s Software versi<strong>on</strong> 2is taken up by giving the sec<strong>on</strong>dary z<strong>on</strong>e axis some freedom to move (al<strong>on</strong>g the <strong>line</strong> c<strong>on</strong>necting the twoz<strong>on</strong>e axes). Such differences can occur because of the accuracy of the measurement of the stagepositi<strong>on</strong>, including the effects of backlash <strong>on</strong> the tilts (which may result in deviati<strong>on</strong>s up to 0.2° or so) orbecause the crystal is bent and the sec<strong>on</strong>d z<strong>on</strong>e axis orientati<strong>on</strong> was not determined from the exactsame place in the crystal.CancelPressing Cancel exits from the Two-z<strong>on</strong>e indexing dialog, while leaving the orientati<strong>on</strong> as it was.7.5.2 Z<strong>on</strong>e axis calculator dialogWhen <strong>on</strong>e of the Calculator butt<strong>on</strong>s is pressed, the software brings up the Z<strong>on</strong>e axis calculator dialog:MeasurementThe Z<strong>on</strong>e Axis Calculator can use the same method for measuring in diffracti<strong>on</strong> as the standardMeasuring c<strong>on</strong>trol panel. Please see the descripti<strong>on</strong> there as to the executi<strong>on</strong> of such measurements.The results of the measurements are automatically inserted into the edit c<strong>on</strong>trols for d1, d2 and theinterplanar angle.d1d1 is the first d-spacing used for indexing of the z<strong>on</strong>e axis. The value for the d-spacing (in nanometers)can be determined with the <strong>on</strong>-<strong>line</strong> measurement or entered by hand.d2d2 is the sec<strong>on</strong>d d-spacing used for indexing of the z<strong>on</strong>e axis. The value for the d-spacing (innanometers) can be determined with the <strong>on</strong>-<strong>line</strong> measurement or entered by hand.RatioWhen Calculate is pressed, the ratio between the two d-spacings as measured is calculated. This valuecan be compared to the calculated value.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!