12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 125Opti<strong>on</strong>s Software versi<strong>on</strong> 29.1.11 Measurement with diffracti<strong>on</strong> shiftThe diffracti<strong>on</strong> shift of the <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> is largely free of hysteresis and can be used to calibrate diffracti<strong>on</strong>spacings, from which camera lengths can be determined. The ring analysis method is usable <strong>on</strong>ly atcamera lengths where the rings in the diffracti<strong>on</strong> pattern are well-separated from the center and are nottoo large for the CCD. The indirect diffracti<strong>on</strong>-shift measurement must therefore be used where the ringsanalysis cannot be d<strong>on</strong>e, that is for the lower and higher camera lengths.Before the diffracti<strong>on</strong> shift can be used to calibrate camera lengths, it must first be calibrated itself. Thisis d<strong>on</strong>e at a suitable camera length, immediately after the camera length there has been calibrated withthe rings. (The software thus does not rely <strong>on</strong> any existing - potentially inaccurate or even wr<strong>on</strong>g -diffracti<strong>on</strong> shift calibrati<strong>on</strong>s in the system.)The procedure followed during diffracti<strong>on</strong> shift calibrati<strong>on</strong> is as follows:• Apply a negative shift from the current diffracti<strong>on</strong>-pattern positi<strong>on</strong> and acquire image 1, with anegative backlash correcti<strong>on</strong> (first more negative, then to the desired positi<strong>on</strong>).• Apply a similar but now positive shift from the original positi<strong>on</strong> and acquire image 2.• Apply a positive shift from the original diffracti<strong>on</strong>-pattern positi<strong>on</strong> and acquire image 3 (positi<strong>on</strong> thesame as image 2), with a positive backlash correcti<strong>on</strong> (first more positive , then to the desiredpositi<strong>on</strong>).• Apply a similar but now negative shift from the original positi<strong>on</strong> and acquire image 4 (positi<strong>on</strong>s thesame as image 1).• Determine the shift between images 1 and 2, and between 3 and 4. These shifts give the two vectorsused for the calibrati<strong>on</strong>.Since drift is not an issue in diffracti<strong>on</strong>, no drift correcti<strong>on</strong> is d<strong>on</strong>e in the diffracti<strong>on</strong>-shift based calibrati<strong>on</strong>.9.2 Magnificati<strong>on</strong> Calibrati<strong>on</strong> Report C<strong>on</strong>trol PanelThe Report tab of the Magnificati<strong>on</strong> Calibrati<strong>on</strong> C<strong>on</strong>trol Panelc<strong>on</strong>tains the c<strong>on</strong>trols used for report generati<strong>on</strong>. All reports are inAcrobat Reader (pdf) file format.Two types of report can be created:• A tabular overview of the results of a calibrati<strong>on</strong> sessi<strong>on</strong>s, displaying the TEM magnificati<strong>on</strong>, themeasured value(s) according to the method used, which value is used for the magnificati<strong>on</strong> table, theassociated c<strong>on</strong>sistency error, and the magnificati<strong>on</strong> factor from plate camera to CCD or the ratiobetween nominal and measured STEM magnificati<strong>on</strong>s..• A graphical overview of the results of (at most) the last twelve calibrati<strong>on</strong>s d<strong>on</strong>e.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!