12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 18Opti<strong>on</strong>s Software versi<strong>on</strong> 2Spot wobbleTo determine what the distances between the spot should be, click <strong>on</strong> Spot wobble. The spot will now bewobbled back and forth and the scroller can be adjusted until the spot just touch each other. The spotdistance is indicated above the spot slider (in arbitrary units when not calibrated, otherwise inmicrometers). The number of spots in the total scan is also indicated.Note: The optimum beam deflecti<strong>on</strong> range (reset when spotscan setup functi<strong>on</strong>s are switched <strong>on</strong>)affects the spot distance. Therefore always check the spot distance after setting the scan range.PreviewThe result of the spotscan setup can be viewed <strong>on</strong> the viewing screen to check that everything is alrightfor the exposure. This functi<strong>on</strong> is available <strong>on</strong>ly in the Low Dose Exposure state (press the Exposurebutt<strong>on</strong>). The progress of the scan is indicated by the progress bar in the top of the panel (blueincreasingly fills the bar).ViewPressing the View butt<strong>on</strong> starts and stops the spot scan.SlowerWhen the Slower butt<strong>on</strong> is pressed, the spot dwell time is increased by a factor 2.FasterWhen the Faster butt<strong>on</strong> is pressed, the spot dwell time is reduced by a factor 2.To 0,0When the butt<strong>on</strong> To 0,0 is pressed, the scan is stopped and the beam is moved to the 0,0 positi<strong>on</strong>(center of the scan frame). If the beam is not centered <strong>on</strong> the screen, it should be shifted to the centerwith the normal beam shift (or Align beam shift alignment). The c<strong>on</strong>trol of the AC beam deflecti<strong>on</strong> coils(used by spotscan) remains <strong>on</strong>.Shift awayWhen the Shift away butt<strong>on</strong> is pressed, the beam will be moved to an extreme X,Y positi<strong>on</strong>. It should notbe visible <strong>on</strong> the screen now (unless the magnificati<strong>on</strong> has been lowered from the exposuremagnificati<strong>on</strong> used during the setup). The c<strong>on</strong>trol of the AC beam deflecti<strong>on</strong> coils (used by spotscan)remains <strong>on</strong>.AC offTo switch the AC coils (used by spotscan) c<strong>on</strong>trol off after the preview, press the AC off butt<strong>on</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!