12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 48Opti<strong>on</strong>s Software versi<strong>on</strong> 2Calibrati<strong>on</strong>s have a set hierarchy (some calibrati<strong>on</strong>s can <strong>on</strong>ly be d<strong>on</strong>e <strong>on</strong>ce others have been d<strong>on</strong>e).They are specific to a number of c<strong>on</strong>diti<strong>on</strong>s :• CCD camera used in combinati<strong>on</strong> with the microscope lens series (Normal or EFTEM)• High tensi<strong>on</strong>• Microscope mode (LM, Microprobe, Nanoprobe, Lorentz)For the microscope modes, <strong>on</strong>ly the Nanoprobe mode does not require full calibrati<strong>on</strong>s. For that mode<strong>on</strong>ly the Focus/Stigmator calibrati<strong>on</strong> must be d<strong>on</strong>e separately (the rest of the calibrati<strong>on</strong>s if the same asin the Microprobe mode).Calibrati<strong>on</strong>s can <strong>on</strong>ly be d<strong>on</strong>e by TEM Experts (private calibrati<strong>on</strong>s for these users) and Supervisor,Service or Factory (dependent <strong>on</strong> availability, these calibrati<strong>on</strong>s are what basic microscope Users get.Calibrati<strong>on</strong> is d<strong>on</strong>e <strong>on</strong> the basis of a standard specimen, a cross-grating. This specimen has squares <strong>on</strong>it with a spacing of 463 nm.3.16.4 Magnificati<strong>on</strong> calibrati<strong>on</strong>The software will acquire an image of the cross-grating and analyse that to find the basic spacing. Theanalysis is d<strong>on</strong>e using an auto-correlati<strong>on</strong> (at high magnificati<strong>on</strong>s) or an FFT (at low magnificati<strong>on</strong>s) inwhich the two basic vectors will be out<strong>line</strong>d by circles.An image of a cross-grating, showing the 463 nm squares.The result of the magnificati<strong>on</strong> calibrati<strong>on</strong>. The autocorrelati<strong>on</strong>of the cross-grating image (zoomed in 2x) shows the centralpeak pointed at by the <strong>line</strong> (which has been added <strong>manual</strong>ly forclarity). The software adds the two circles around the two basevectors of the pattern. It is important that these circles arelocated at the correct positi<strong>on</strong>s and not e.g. at the diag<strong>on</strong>als ofthe squares. Additi<strong>on</strong>al circles are placed at the multiples of thebase vectors used to show how many base vectors were usedtogether for the analysis.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!