12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 119Opti<strong>on</strong>s Software versi<strong>on</strong> 29.1.2 The Mi plus SA magnificati<strong>on</strong> calibrati<strong>on</strong> procedureThe calibrati<strong>on</strong>s procedure c<strong>on</strong>sists of a calibrati<strong>on</strong> for each magnificati<strong>on</strong> of the series. The followingprocedure is used:• Direct cross-grating calibrati<strong>on</strong> of the lowermost SA magnificati<strong>on</strong>.• Calibrati<strong>on</strong> of the image shift at the lowermost SA magnificati<strong>on</strong> (this does not calibrate amagnificati<strong>on</strong>, but the image shift itself, used later).• Calibrati<strong>on</strong> of the Mi magnificati<strong>on</strong>s with the cross-grating method.• Calibrati<strong>on</strong> of the remaining SA magnificati<strong>on</strong>s, going up in magnificati<strong>on</strong> up to the point where themagnificati<strong>on</strong> <strong>on</strong> the CCD camera is larger than 250kx. The software detects the magnificati<strong>on</strong> atwhich the cross-grating method does not work anymore and displays a warning in that sense. Thenthe software automatically switches to the image shift method which will be used for the remainingSA magnificati<strong>on</strong>s.9.1.3 The LM magnificati<strong>on</strong> calibrati<strong>on</strong> procedureThe calibrati<strong>on</strong>s procedure c<strong>on</strong>sists of a calibrati<strong>on</strong> for each magnificati<strong>on</strong> of the series down to amagnificati<strong>on</strong> of 200x <strong>on</strong> the CCD. The procedure uses an analysis of the FFT of the cross-grating todetermine the magnificati<strong>on</strong>s.9.1.4 The D camera length calibrati<strong>on</strong> procedureThe calibrati<strong>on</strong>s procedure c<strong>on</strong>sists of a calibrati<strong>on</strong> for the camera lengths of the series (in the case ofEFTEM the lowermost camera lengths are excluded from the calibrati<strong>on</strong> because they often are notusable - the projecti<strong>on</strong> system reducti<strong>on</strong> is so str<strong>on</strong>g that it becomes impossible to get the electr<strong>on</strong> beamthrough the differential pumping aperture). The following procedure is used:• Direct calibrati<strong>on</strong> of the diffracti<strong>on</strong> rings of a cross-grating at a camera length selected by software <strong>on</strong>the basis of CCD camera size and high tensi<strong>on</strong>.• Calibrati<strong>on</strong> of the diffracti<strong>on</strong> shift at that camera length (this does not calibrate a camera length, butthe diffracti<strong>on</strong> shift itself, used later).• Calibrati<strong>on</strong> of the lowermost camera lengths with the diffracti<strong>on</strong> shift (the rings are too close to thecenter of the diffracti<strong>on</strong> pattern).• Calibrati<strong>on</strong> of the rings for the camera lengths where the rings are well enough separated from thecenter but not so large that they are no l<strong>on</strong>ger visible <strong>on</strong> the CCD.• Calibrati<strong>on</strong> of the higher camera lengths with the diffracti<strong>on</strong> shift (the rings are too large to fit <strong>on</strong> theCCD).If possible, the procedure will be run in the Nanoprobe mode, because the large illuminated area forparallel illuminati<strong>on</strong> in Microprobe is so large that it often leads to the appearance of severe distorti<strong>on</strong>s inthe center of the pattern. It is important to focus the pattern so the rings becomes as sharp as possible.The focusing in Nanoprobe should be d<strong>on</strong>e with the Intensity - provided the camera lengths are focusedprior, which should have been d<strong>on</strong>e in the Image HM-TEM Camera Length alignment procedure.Note: The software is not suitable for calibrati<strong>on</strong> of the LAD (LM) camera lengths nor for the Lorentzmode camera lengths.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!