12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 138Opti<strong>on</strong>s Software versi<strong>on</strong> 210.4 AutoGun C<strong>on</strong>trol (Expert) – (Thermi<strong>on</strong>ic)The AutoGun C<strong>on</strong>trol Panel provides a number of systemsettings c<strong>on</strong>cerning the filament as well as access to theC<strong>on</strong>diti<strong>on</strong>ing procedure.FilamentThe filament type can either be Tungsten or LaB 6 . The type of filament can <strong>on</strong>ly be chosen by theSupervisor.Filament limitThe filament limit is the value up to which the filament setting can be increased before it stopsautomatically. The value can be adjusted by Expert user and Supervisor.C<strong>on</strong>diti<strong>on</strong> statusIt is not always possible to start the c<strong>on</strong>diti<strong>on</strong>ing procedure. The C<strong>on</strong>diti<strong>on</strong> status indicates whyc<strong>on</strong>diti<strong>on</strong>ing is not possible (apart from another procedure currently running). If c<strong>on</strong>diti<strong>on</strong>ing is possible,the c<strong>on</strong>diti<strong>on</strong> status is not visible and the C<strong>on</strong>diti<strong>on</strong> butt<strong>on</strong> is enabled.C<strong>on</strong>diti<strong>on</strong>Pressing the C<strong>on</strong>diti<strong>on</strong> butt<strong>on</strong> starts or stops the C<strong>on</strong>diti<strong>on</strong>ing procedure. The color of the butt<strong>on</strong>indicates the status (yellow = active).C<strong>on</strong>diti<strong>on</strong> toThe value for c<strong>on</strong>diti<strong>on</strong> to is the goal used by the c<strong>on</strong>diti<strong>on</strong>ing procedure. For Experts the suggestedvalue is the maximum high tensi<strong>on</strong> plus 5% if an overvoltage is possible (200 and 300kV), otherwise it isthe maximum high tensi<strong>on</strong>.C<strong>on</strong>diti<strong>on</strong> delay stepThe c<strong>on</strong>diti<strong>on</strong> delay step defines the number of sec<strong>on</strong>ds the c<strong>on</strong>diti<strong>on</strong>ing procedure will before it takesanother step (subject to the vacuum pressure being low enough).Filament hour counterThe filament hour counter displays the date the filament was installed and the number of hours thefilament has been in operati<strong>on</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!