12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 76Opti<strong>on</strong>s Software versi<strong>on</strong> 25.6.5 Help menuThe Help menu c<strong>on</strong>tains two items, Show and About. Selecting Show (or pressing F1) will display thisHelp file in the <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> User Interface. About will display the About TEM Smart Tilt dialog listing thecurrent versi<strong>on</strong> number of the software. When reporting bugs, always include the versi<strong>on</strong> number in thereport.5.7 Camera length calibrati<strong>on</strong>The rotati<strong>on</strong> calibrati<strong>on</strong> c<strong>on</strong>sists of a simple procedure to determine the orientati<strong>on</strong> of the diffracti<strong>on</strong>pattern relative to the viewing screen. The procedure for a single camera length c<strong>on</strong>sists of two steps. Inthe first step, the diffracti<strong>on</strong> pattern must be centered accurately <strong>on</strong> the screen with the Multifuncti<strong>on</strong> X,Yknobs. Once that is d<strong>on</strong>e the following dialog appears.The central beam in the diffracti<strong>on</strong> pattern must now be shifted to the marker indicated (or as far aspossible in the directi<strong>on</strong> of the marker). Note that the distance shifted is not relevant, it is the directi<strong>on</strong>that is important.In the procedure for all camera lengths, the software goes through the same procedure for all cameralengths.5.8 Alpha and beta tilt calibrati<strong>on</strong>In order for the program to display the orientati<strong>on</strong> of the tilt axes <strong>on</strong> the screen and determine the tiltsrequired when the diffracti<strong>on</strong> shift is used, it is necessary to calibrate the tilt axes. In these procedures(unlike the rotati<strong>on</strong> calibrati<strong>on</strong>), it is not <strong>on</strong>ly the directi<strong>on</strong> that is important but also the magnitude of theshift.The tilt calibrati<strong>on</strong> procedure c<strong>on</strong>sists of the following steps (all executed after instructi<strong>on</strong>s from theprogram):• Tilt a crystal to a z<strong>on</strong>e axis that is well-defined and will be recognisable from the Kikuchi pattern evenwhen tilted off axis.• Center the diffracti<strong>on</strong> pattern accurately.• Tilt the z<strong>on</strong>e axis away as far as possible (the higher the tilt away from z<strong>on</strong>e axis, the more accuratethe calibrati<strong>on</strong> will be) with <strong>on</strong>e tilt axis <strong>on</strong>ly, while still being able to recognise it.• With the diffracti<strong>on</strong> shift recenter the z<strong>on</strong>e axis (the intersecti<strong>on</strong> of the Kikuchi bands) <strong>on</strong> the screen.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!