12.07.2015 Views

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

Tecnai on-line help manual -- Options - UT Southwestern

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> <strong>on</strong>-<strong>line</strong> <strong>help</strong> Opti<strong>on</strong>s 9Opti<strong>on</strong>s Software versi<strong>on</strong> 2These butt<strong>on</strong>s and knobs are assigned in the Opti<strong>on</strong>s tab of the Low Dose flap-out. Low Dose keepstrack of any other assignment to these butt<strong>on</strong>s and knobs (e.g. <strong>on</strong> alignment or stigmati<strong>on</strong>). If a butt<strong>on</strong> orknob is given another functi<strong>on</strong>, its will no l<strong>on</strong>ger affect Low Dose (so pressing L1 when the L1 functi<strong>on</strong>has been changed doesn't switch to Search anymore). As so<strong>on</strong> as the butt<strong>on</strong> or knob has beenreleased, it gets back its Low Dose functi<strong>on</strong>ality.When Low Dose is stopped (by pressing the Low Dose butt<strong>on</strong> or exiting the <str<strong>on</strong>g>Tecnai</str<strong>on</strong>g> User Interface), thebutt<strong>on</strong>s and knobs get back their original setting.1.1.7 User levels in Low DoseThe Low Dose software supports two user levels, 'user' and 'supervisor'. Supervisor settings (both LowDose settings and calibrati<strong>on</strong>s) are stored separately from those of the user. When a new user startsLow Dose for the first time, the settings and calibrati<strong>on</strong>s used are those defined by the supervisor.Thereafter the user has set his/her own settings and these will be retrieved when the software is started.The <strong>on</strong>ly way thereafter to go back to the supervisor settings is to have the supervisor save settings andcalibrati<strong>on</strong>s files and load these files as a user. Low Dose settings and calibrati<strong>on</strong>s saved by Factory orService are equivalent to Supervisor settings.1.1.8 SpotscanSpotscan (FP5408/00) is an opti<strong>on</strong> for the Low Dose software. It relies <strong>on</strong> hardware installed in themicroscope PC and microscope and will not functi<strong>on</strong> without the proper hardware.The Low Dose versi<strong>on</strong> with spotscan supports two modes of exposure:• The normal 'flood-beam' exposure wherein the whole exposure area is illuminated by a broad beamand exposed together.• The spotscan exposure wherein a smaller beam is stepped across the area to be exposed and eachspot is exposed individually.Spotscan settings are defined in the Spotscan tab of the Low Dose C<strong>on</strong>trol Panel flap-out.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!