Section 4: Troubleshooting<br />

DETCTRS ON LONG<br />

Symptom:<br />

While replenishing, more than one detector was blocked too long.<br />

Corrective Action:<br />

During the last replenish cycle, the system detected a coin pulse from the dispenser that was much longer than normal.<br />

Most likely, an incorrect change load has been deposited into one of the change buckets.<br />

1. A detector LED could have burned out during the replenish cycle. If the LEDs are lit, reset the bill changer<br />

and see if it goes back into SHUTDOWN. If so, refer to new status message that will appear.<br />

2. If the bill changer stays in service, then check the photo detectors (per Section 3) and wiring.<br />

3. If all three LEDs are not lit, check the +5 VDC LED on the power supply. If the +5 VDC LED is OFF, check<br />

the power supply. If the +5 VDC LED is ON, check the harness.<br />

4. Also, check the upper coin chute for anything that would hold a coin up and block the detectors.<br />

5. If everything looks OK, replace the CCC.<br />

6. To restore the bill changer to service, press the FUNCTION button after correcting the problem.<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 040 at the end of this<br />

DETECTOR troubleshooting.<br />

25238801 4-37