Section 4: Troubleshooting<br />
Chart 100 - Shutdown - Out Of Service Lamp Lit<br />
Display shows: BUCKET STAYS ON<br />
One of the bucket solenoids was energized too long during a normal vend. Most likely,<br />
there is an incorrect change load in one of the buckets.<br />
Press the FUNCTION button. Does the machine shut down with the message "BUCKET<br />
POWER ON"?<br />
NO<br />
Try several test vents from each of the three buckets.<br />
Does one cause this shutdown?<br />
YES<br />
See chart titled "BUCKET POWER ON".<br />
NO<br />
YES<br />
Possible defective CCC.<br />
OR<br />
Intermittent short from the R/B, Y/BR, or<br />
BL/W wire to Ground.<br />
Check the suppression diode and wiring<br />
associated with the bucket that caused<br />
the shutdown. NOTE: Disconnect the<br />
bucket solenoid from the dispenser<br />
when testing the diode.<br />
IF OK<br />
Replace the CCC. See CAUTION.<br />
CAUTION:<br />
Installing a new CCC without determining the cause of the failure may destroy the new board. Use<br />
an ohmmeter to determine if it is safe to install a new CCC. If you use an ohmmeter, check for shorts<br />
(less than seven ohms) between the V/O wire, Y/BR, and BL/W or Ground.<br />
25238801 4-55