<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

BUCKET PWR FLT<br />

Symptom:<br />

One of the bucket coils was detected active when it should not be.<br />

Corrective Action:<br />

Machine has been shut down because one or more of the bucket solenoids were energized during standby. Most<br />

likely, one of the buckets has an incorrect change load.<br />

1. Check R813 on the power supply assembly for possible shorts to the chassis.<br />

2. Check C816 on the power supply circuit board for excess leakage.<br />

3. Check for a faulty CCC or a short in the wiring to the buckets.<br />

4. Also check for a faulty suppression diode on the dispenser.<br />

5. Check the diodes.<br />

6. To restore the machine to service, press the FUNCTION button after correcting the problem.<br />

Use a volt-ohmmeter in accordance with the troubleshooting chart for this error to establish whether on not it is safe<br />

to install a replacement CCC 1 .<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 080 on the next page.<br />

1<br />

Installing a replacement CCC in the machine without determining the cause of the original failure may destroy the<br />

replacement CCC.<br />