<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />
16. Press the FUNCTION button to advance to the BILL B CHECK ON/OFF mode selection. Press either the ^ or<br />
button to switch between the ON and OFF mode.<br />
^<br />
The normal position for standard validation (BILL B CHECK ON) provides maximum security against bogus<br />
bills. This is the factory setting and <strong>Rowe</strong> strongly recommends its use for all but the most severe<br />
environments.<br />
The BILL B CHECK OFF position improves acceptance of bills which are contaminated with metal chips or<br />
dust, but also reduces protection against bogus bills.<br />
17. Press the FUNCTION button to advance to the BILL TEST ON/OFF mode selection. Press either the ^ or<br />
button to switch between ON and OFF.<br />
The BILL TEST mode will allow you to test bill acceptance without disturbing any of the other machine<br />
functions.<br />
If the BILL TEST is not desired, leave the mode set to OFF and go on to Step 18.<br />
To operate under the BILL TEST mode, leave the option ON then move the slide switch to the normal<br />
position. The display will show “STORING NEW DATA”, then “BILL TEST MODE”. At this time, any bills<br />
inserted into the transport will be validated normally. If the bill is accepted, it will be stacked in the bill<br />
stacker and the display will show “GOOD $X”, where X is the denomination just accepted. The machine will<br />
not payout change, will not advance the dollars accepted counter, and will not advance the audit totals while<br />
in the BILL TEST mode.<br />
If a bill is rejected, the display will show the normal reject message. See Section 4 for an explanation of the<br />
reject messages.<br />
There are three ways to leave the BILL TEST mode: You can go back into the PROGRAMMING mode and<br />
set the BILL TEST mode to OFF, or you can simply turn the POWER switch OFF then back ON. The third<br />
way is a safety feature where the machine will automatically return to the NORMAL mode two minutes after<br />
the last test bill was inserted (remains “IDLE” for 2 minutes).<br />
18. Pressing the FUNCTION button will send the computer back to the beginning of the entire programming<br />
sequence (“TEMP COUNTERS” will show on the display) and you may review your setup by stepping<br />
through each function again.<br />
To return the bill changer to normal operation, move the slide switch from the PROGRAMMING position to the<br />
NORMAL position. The display will show “STORING NEW DATA” and then the “walking dash” again.<br />
^<br />