<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

L DETCTR ON LONG<br />

Symptom:<br />

While replenishing, the left detector was blocked too long.<br />

Corrective Action:<br />

During the last replenish cycle, the system detected a coin pulse from the dispenser that was much longer than normal.<br />

Most likely, an incorrect change load has been deposited into one of the change buckets.<br />

1. A detector LED could have burned out during the replenish cycle. If the LEDs are lit, reset the bill changer<br />

and see if it goes back into SHUTDOWN. If so, refer to new status message that will appear.<br />

2. If the bill changer stays in service, then check the left photo detector (per Section 3) and wiring.<br />

3. Also, check the upper coin chute for anything that would hold a coin up and block the detector.<br />

4. If everything looks OK, replace the CCC.<br />

5. To restore the bill changer to service, press the FUNCTION button after correcting the problem.<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 040 at the end of this<br />

DETECTOR troubleshooting.<br />

4-34 25238801