<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />
Transport Errors<br />
Transport errors are considered to be recoverable errors. That is, if the source of the error goes away, the machine<br />
will return to the normal STANDBY mode all by itself. Transport errors are shown on the status display while they<br />
are present. Occasionally after resetting a shutdown error or on power up, a transport error will briefly appear. This<br />
is normal and should not be a concern. A list of transport errors follows with an explanation for each and hints on<br />
where to look for trouble.<br />
CLEARING ERRORS<br />
Transport errors are self-clearing. When the trouble has been repaired, the error will go away on its own.<br />
Bill changer errors are stored in the CCC and must be cleared. To clear an error displayed on the readout, push<br />
the FUNCTION button on the CCC while the CCC is in the NORMAL mode. If the situation that caused the error<br />
is repaired, the error will be cleared. Multiple errors will be stored in the CCC. Press the FUNCTION button to clear<br />
each error as it is displayed on the CCC readout (referred to as the “display”). When all errors are cleared, the<br />
changer will return to STANDBY.<br />
CK TRANSPORT MAG<br />
Symptom:<br />
The Mag. amp output idle voltage is not within limits (0.24 to 1.60 volts).<br />
Corrective Action:<br />
1. Check the wires and connectors in the Mag. amp and transport harness.<br />
2. Replace the Mag. amp circuit board.<br />
3. Replace the transport.<br />
4. Replace the CCC.<br />
CK TRANSPORT VI<br />
Symptom:<br />
The transport inlet cell voltage is not within limits (0 to 4.10 volts).<br />
Corrective Action:<br />
1. Check the Yellow wire and connectors in the transport harness for an open/short back to the CCC P4 pin 14.<br />
2. Check the VI cell for proper voltage and switching (refer to Section 3).<br />
3. Replace the inlet cell.<br />
4. Replace the transport.<br />
5. Replace the CCC.<br />
4-20 25238801