<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

Bill Stacker Problems<br />

Does the stacker motor run at all?<br />

YES<br />

The stacker cam switches are out of<br />

adjustment. See the adjustment<br />

procedures in Section 3 of this manual.<br />

OR<br />

Defective driver board in the stacker.<br />

OR<br />

Defective stacker cam switch.<br />

OR<br />

A harness problem exists inside the<br />

stacker. Replace the stacker.<br />

NO<br />

In addition to the steps at the left, check<br />

the following:<br />

OR<br />

Defective stacker motor.<br />

OR<br />

Open condition in one or more of the<br />

following lines:<br />

G/O from the computer board to the<br />

stacker.<br />

Red from the power control center P203 to<br />

the stacker.<br />

Black from the stacker to P202.<br />

W and W/B (120VAC) from the stacker to<br />

the power control center P204.<br />

4-62 25238801