29.09.2014 Views

BC-3500 Series - Rowe International

BC-3500 Series - Rowe International

BC-3500 Series - Rowe International

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

VALIDATION REJECTS<br />

Cell Sequence Rejects<br />

REJECT - SHORT VI<br />

Symptom:<br />

The inlet cell was covered for too short of a time.<br />

This is a reject message.<br />

The bill was rejected because the VI cell was not covered long enough. The bill may have been torn on the right<br />

side, torn, or folded over at the trailing edge of the bill. If bills are rejected frequently with this code, the VI cell may<br />

be giving an intermittent signal.<br />

Corrective Action:<br />

1. Check the VI cell for proper switching.<br />

2. If the cell is OK, check the wiring from the VI cell to the CCC for a possible short to the chassis, or an open<br />

to the CCC (P4 - Pin 14).<br />

3. The +5 VDC supply to the LEDs may be below 4.5 VDC; check the voltage. If it is low, replace regulator<br />

VR802 on the power control center (see the components list for the power supply circuit board).<br />

4. If all of preceding checks are OK, replace the CCC.<br />

If the bill is left in the transport for five seconds, the machine will go into SELF-CLEAR.<br />

4-6 25238801