Section 4: Troubleshooting<br />

CK BILL RETRN SW<br />

Symptom:<br />

The bill return switch was closed longer than 10 seconds. This error will disable the bill return function. All other<br />

changer functions continue to operate.<br />

Corrective Action:<br />

1. Remove the bind or jam in the bill return linkage.<br />

2. Check the R/G wire from the bill return to CCC (P5 Pin 9) for a short to ground.<br />

3. Check the bill return switch. If it is defective, replace it. If it is not defective, replace the CCC.<br />

Bill Changer Errors (Shutdown)<br />

Only one of these errors will exist at a time. The display will flash the error code indicating a SHUTDOWN. One of<br />

these errors may also exist with up to three NON-SHUTDOWN errors.<br />

COIN DETECTOR ERRORS WHILE IN THE STANDBY MODE<br />

CK L COIN DETCTR<br />

Symptom:<br />

The left coin detector was blocked while the bill changer was in the STANDBY state. One of the buckets may have<br />

an incorrect change load.<br />

Corrective Action:<br />

The left coin photodetector input is, or was, giving an incorrect signal / or the left hopper may have been running in<br />

standby mode.<br />

1. The left LED on the dispenser may have burned out. If the LED is still out, check the wiring to that LED. Check<br />

the LED and replace it if it is defective.<br />

2. If all LEDs are not lit, check the +5 VDC LED on the power control center. If it is not lit, check the power supply.<br />

If it is lit, check +5V power distribution lines in the harness (Blue wires).<br />

3. Press the FUNCTION button. If the message reappears, check for dirt on the left detector and LED. If they<br />

are clean, check the coin photodetector (per Section 3). If it is OK, check the wiring from the photodetector<br />

to the CCC for an open connection or short to Ground. If no problems are found, replace the CCC.<br />

25238801 4-29