Section 4: Troubleshooting<br />

REJECT - LOST TACH<br />

Symptom:<br />

The tach signal from the transport was lost.<br />

This is a reject message.<br />

The bill was rejected because the CCC cannot control the transport motor speed without a tach. signal.<br />

Corrective Action:<br />

1. An object is possibly hung-up or jammed in the track.<br />

2. Check for a tach. signal as outlined in Test Procedures in Section 3. Replace the transport if the tach. is bad.<br />

3. Check for intermittent connections in the wiring from the transport to the CCC (P4- Pin 9).<br />

4. If all of the preceding checks are OK, replace the CCC.<br />

REJECT - VF OPEN<br />

Symptom:<br />

The flipper cell opened too soon.<br />

This is a reject message.<br />

The bill was rejected because the VF cell opened during validation.<br />

The bill is possibly torn, or it may have a hole in it.<br />

An object is possibly hung-up or jammed in the track near the flipper.<br />

If bills are frequently rejected for this message, take the following corrective action:<br />

Corrective Action:<br />

1. Check for tight, binding, or sticky flipper operation.<br />

2. Check for an intermittent open circuit in the wiring to the VF cell from CCC (P4- pin 7).<br />

3. If the preceding checks do not find the problem, replace the CCC.<br />

If a bill is left in the transport for five seconds, the bill changer will go into SELF-CLEAR.<br />

25238801 4-15