<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

REJECT - NO MAG<br />

Symptom:<br />

Not enough magnetic signal from the Mag. Amp.<br />

This is a reject message.<br />

The bill was rejected because no signals came from the Mag. Amp.<br />

The bill may have been inserted upside down.<br />

If bills are frequently rejected for this message:<br />

Corrective Action:<br />

1. Check for intermittent connections in the Mag. Amp. harness or the White/Brown, White/Green wires from<br />

the transport to the CCC (P4 - Pins 2 and 5).<br />

2. Check the bill pressure rollers in the transport for proper spring pressure.<br />

3. Check the surface of the Mag. head for dirt buildup or foreign material.<br />

4. If all of the preceding checks are OK, replace the Mag. Amp.<br />

5. If the problem still exists, replace the CCC.<br />

If a bill is left in the transport for five seconds, the bill changer will go into SELF-CLEAR.<br />