BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Section 4: Troubleshooting<br />
Bill Transport Fails to Run in One or Both Directions<br />
(Works OK for Coins and Test Switches)<br />
Does the transport run in one direction?<br />
NO<br />
YES<br />
Does the motor hum?<br />
Does the transport run forward?<br />
NO<br />
YES<br />
NO<br />
YES<br />
Check the wire from J202<br />
pin 1 to P3 pin 2 for an<br />
open circuit.<br />
NO<br />
Check for +12VDC at<br />
J202 pin 1.<br />
NO<br />
Replace the<br />
power control<br />
center.<br />
YES<br />
Are the timing belts<br />
too tight?<br />
YES<br />
NO<br />
Replace the<br />
motor.<br />
Adjust the timing belt<br />
tension following the<br />
procedure in Section 3<br />
of this manual.<br />
Cover the VI cell.<br />
Does the display show<br />
"VALIDATING"?<br />
Check the VI<br />
cell (Section 3).<br />
Check the<br />
Yellow wire<br />
at J706 pin<br />
7 for a short<br />
to Ground.<br />
NO YES NO<br />
IF OK<br />
Check the transport<br />
motor + and - from P1<br />
pins 2 and 3 to J701<br />
pins 11 and 12 for an<br />
open circuit.<br />
Replace<br />
the main<br />
harness.<br />
YES<br />
Does the transport run<br />
in a runaway condition?<br />
NO<br />
Replace<br />
the CCC.<br />
YES<br />
Check for an open circuit<br />
between P706 pins 1-13 and<br />
J701 pins 1-13.<br />
YES<br />
NO<br />
Replace<br />
the CCC.<br />
IF OK<br />
Check the transport<br />
encoder wiring at<br />
J706 pin 9 to P4 pin 9.<br />
Is there an open<br />
circuit?<br />
Replace the<br />
transport<br />
harness<br />
assembly.<br />
Check for voltage between<br />
J701 pins 11 and 12 while<br />
covering VI. Is voltage<br />
present?<br />
YES<br />
Replace/repair<br />
the main harness.<br />
NO<br />
Replace<br />
the CCC.<br />
NO<br />
Check the main<br />
harness wiring<br />
for continuity of<br />
motor wires.<br />
YES<br />
Replace the<br />
motor.<br />
YES<br />
Replace the<br />
CCC.<br />
25238801 4-57