Section 4: Troubleshooting<br />

Chart 010 — No Test Switch Response<br />

Display shows: CK LEFT TEST SW – OR – CK CTR TEST SW<br />

– OR – CK RIGHT TEST SW – OR – CK TEST SWITCHES<br />

The bill changer doesn't respond to the test switches because one of the TEST switch<br />

inputs to the computer is, or was, showing an incorrect signal.<br />

Press the FUNCTION button. Does the message reappear?<br />

NO<br />

Check for an intermittent short to Ground<br />

on the R/W, V/W, and BR/W wires from P4<br />

and P5 to the power control center. Check<br />

the wiring inside the power control center<br />

from P204 to the power supply circuit<br />

board.<br />

IF OK<br />

Possible defective power supply board or<br />

CCC.<br />

YES<br />

Check for a short on R/W, V/W, and BR/W<br />

wires from the CCC to Ground.<br />

YES<br />

Remove the Y/W wire from P5 and the R/W,<br />

BR/W wires from P4 to the CCC. Push the<br />

FUNCTION button. Does the code<br />

reappear?<br />

YES<br />

NO<br />

Replace the CCC.<br />

Replace the power<br />

supply board.<br />