<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

BILL PARAMETER REJECTS<br />

Take corrective action only if all bills or a significant number of bills reject for the same reason. Be sure to try different<br />

bills and bills of different denominations. If they accept, the bill being rejected has some property the CCC finds<br />

abnormal.<br />

REJECT - BILL (A)<br />

Symptom:<br />

The bill failed validation because of a lack of a magnetic signal.<br />

Corrective Action:<br />

1. Replace the Mag. amp/transport<br />

2. Replace the CCC.<br />

REJECT - BILL (B)<br />

Symptom:<br />

The bill failed validation.<br />

Corrective Action:<br />

1. Replace the Mag. amp/transport<br />

2. Check/clean the two bill pressure rollers under the magnetic head(s) -(may have metal particle contamination).<br />

3. Replace the CCC.<br />

REJECT - BILL (C)<br />

Symptom:<br />

The bill failed validation.<br />

Corrective Action:<br />

1. Replace the Mag. amp/transport<br />

2. Check for good spring tension on the two bill pressure rollers under the magnetic head(s).<br />

3. Replace the CCC.<br />

4-16 25238801