BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />
CK COIN DETECTORS<br />
Symptom:<br />
More than one coin detector was blocked while the bill changer was in STANDBY. One of the buckets may have<br />
an incorrect change load, or one of the hopper motors may have been running in standby mode.<br />
Corrective Action:<br />
More than one of the coin photodetector inputs is, or was, giving an incorrect signal.<br />
1. One of the LEDs on the dispenser may have burned out. If any LEDs are out, check the wiring to that LED.<br />
Check the LEDs and replace any defective LEDs.<br />
2. If all LEDs are not lit, check the +5 VDC LED on the power control center. If it is not lit, check the power supply.<br />
If it is lit, check +5V power distribution lines in the harness (Blue wires).<br />
3. Press the FUNCTION button. If the message reappears, check for dirt on the detectors and LEDs. If they are<br />
clean, check the coin photodetectors (per Section 3). If they are OK, check the wiring from the photodetectors<br />
to the CCC for open connections or shorts to Ground. If no problems are found, replace the CCC.<br />
4. If this message does not reappear after resetting the bill changer, check the wiring to the hopper motors and<br />
coin detectors. If no problems are found, replace the CCC. To restore the bill changer to operation, press<br />
the FUNCTION button after correcting the problem.<br />
NOTE:<br />
This error code may be the result of a leaky output to the hopper drive motor from the CCC. If this is<br />
the case, replace the CCC.<br />
For a more complete troubleshooting sequence, refer to Troubleshooting Chart 030 at the end of this COIN<br />
DETECTOR troubleshooting.<br />
4-32 25238801