BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
BC-3500 Series - Rowe International
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />
One or More Hopper Motors Fail to Run<br />
Do any of the hopper motors run?<br />
NO<br />
Press the FUNCTION button and test vend using a<br />
dollar bill. Does the stacker operate?<br />
YES<br />
NO<br />
YES<br />
Determine which motor does not run. Program to test<br />
for $1.00. Does the display indicate HOPPER<br />
PROBLEMS?<br />
YES<br />
NO<br />
Check for an open circuit<br />
from P402 pins 1, 2, and 3<br />
to the dispenser motors.<br />
See CAUTION.<br />
Stuck contact on the power<br />
control center board.<br />
Replace the relay with the<br />
part indicated in the Parts<br />
Catalog.<br />
Check the wiring associated<br />
with the faulty hopper from<br />
P1 pins 7, 9, and 11 to J402<br />
pins 3, 2, and 1 for an open<br />
circuit.<br />
OR<br />
OR<br />
IF OK<br />
Check for an open circuit<br />
from power control center<br />
J204 pin 4 to CCC P3 pin 8<br />
120 VAC return (White<br />
wire). See CAUTION.<br />
Defective wiring in the<br />
power supply. replace the<br />
power control center.<br />
Defective motor.<br />
OR<br />
Defective computer board.<br />
Replace the CCC.<br />
OR<br />
Replace the CCC.<br />
WARNING:<br />
120 VAC circuitry. Turn the power OFF and pull the<br />
plug from the wall before making this check.<br />
4-56 25238801