Section 4: Troubleshooting<br />

Chart 070 - Shutdown - Out Of Service Lamp Lit<br />

Display shows: CK STACKER<br />

The bill stacker monitor line to the computer is active.<br />

Leave the power ON. Disconnect plug P501 at the side of the bill stacker. Press the<br />

FUNCTION button on the CCC. Does the machine return to service?<br />

YES<br />

Defective bill stacker. Replace with a new<br />

bill stacker or see chart titled "BILL<br />

STACKER PROBLEMS".<br />

NO<br />

Check the G/W wire from the CCC (J4-8) to<br />

the stacker plug. Check for grounded<br />

condition.<br />

IF OK<br />

Defective computer board; replace the CCC.<br />

NOTE:<br />

The machine can be returned to service by turning the<br />

power OFF and correcting the problem. (In some<br />

cases, the FUNCTION button may have to be<br />

pressed.)<br />