<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />
EXTRA COIN - L HOP<br />
Symptom:<br />
More than one extra coin was detected passing through the left detector.<br />
Corrective Action:<br />
Since last time bill changer was reset, the bill changer may have dispensed two more coins than it should have during<br />
the replenish cycle. One of the buckets could have an incorrect change load.<br />
1. Most likely, the problem is not electrical. Probable causes are: Faulty hopper motor brakes, or worn parts<br />
on hopper motors.<br />
2. Also, the possible cause could be intermittent connections to the coin detectors, detector LEDs, or wiring.<br />
3. To restore the bill changer to operation, press the FUNCTION button after correcting the problem.<br />
For a more complete troubleshooting sequence, refer to Troubleshooting Chart 050 at the end of this EXTRA<br />
COIN troubleshooting.<br />
EXTRA COIN - C HOP<br />
Symptom:<br />
More than one extra coin was detected passing through the center detector.<br />
Corrective Action:<br />
Since last time bill changer was reset, the bill changer may have dispensed two more coins than it should have during<br />
the replenish cycle. One of the buckets could have an incorrect change load.<br />
1. Most likely, the problem is not electrical. Probable causes are: Faulty hopper motor brakes, or worn parts<br />
on hopper motors.<br />
2. Also, the possible cause could be intermittent connections to the coin detectors, detector LEDs, or wiring.<br />
3. To restore the bill changer to operation, press the FUNCTION button after correcting the problem.<br />
For a more complete troubleshooting sequence, refer to Troubleshooting Chart 050 at the end of this EXTRA<br />
COIN troubleshooting.<br />
4-40 25238801