Section 4: Troubleshooting<br />

REJECT - NO DENOM<br />

Symptom:<br />

Bills are rejected with this code when the validation tests cannot accurately determine the bill’s denomination.<br />

Corrective Action:<br />

1. Replace the transport.<br />

2. Replace the CCC.<br />

REJECT - FAST FEED<br />

Symptom:<br />

The bill is being rejected because its acceptance would exceed the limits established for the Fast-Feed Shutdown<br />

feature. (See Section 2.) The changer will enter the Fast-Feed Shutdown mode as soon as the bill is cleared from<br />

the transport.<br />

REJECT - RETURN SW<br />

Symptom:<br />

The bill return switch was pushed during validation.<br />

Corrective Action:<br />

1. Do not push BILL RETURN switch during validation. Check for loose or shorted wires or a shorted switch.<br />

2. If the switch and wires are OK, replace the CCC.<br />

REJECT - ACCPT OFF<br />

Symptom:<br />

Bill denomination payout was not turned ON.<br />

Corrective Action:<br />

Set the bill changer to accept the rejected denomination.<br />