Section 4: Troubleshooting<br />

REJECT - TIMEOUT<br />

Symptom:<br />

Inlet cell was never uncovered.<br />

This is a reject message.<br />

The bill was rejected because the VI cell never uncovered. The CCC recognized this as a non-valid validation<br />

sequence. Take the following corrective action if bills are rejected frequently with this code.<br />

Corrective Action:<br />

1. Check for small pieces of paper or other foreign objects in the track.<br />

2. The VI cell may be giving an intermittent signal. Check the VI cell for proper switching.<br />

3. If the cell is OK, check the wiring from the VI cell to the CCC (P4 - Pin 14) for a possible short to the chassis.<br />

4. The +5VDC supply to the LEDs may be low; check the voltage. If it is low, replace the VR801 regulator on<br />

the power supply board, which is inside the power control center.<br />

5. If all of the preceding checks are OK, replace the CCC.<br />

If a bill is left in the transport for five seconds, the bill changer will go into SELF-CLEAR.<br />