Section 4: Troubleshooting<br />

REJECT - BILL (D)<br />

Symptom:<br />

The bill failed validation.<br />

Corrective Action:<br />

1. Replace the Mag. amp/transport<br />

2. Replace the CCC.<br />

REJECT - BILL (E)<br />

Symptom:<br />

The bill failed validation.<br />

Corrective Action:<br />

1. Check the VR/VT cells for proper voltages and switching (refer to Section 3).<br />

2. Replace the VR cell, VT cell, VR/VT LED or transport.<br />

3. Replace the CCC.<br />

REJECT - BILL (F)<br />

Symptom:<br />

The bill failed validation because there is far too much magnetic signal. Refer to REJECT - BILL (B).<br />

REJECT - BILL (G)<br />

Symptom:<br />

The bill failed validation.<br />

Corrective Action:<br />

1. Check the VR/VT cells for proper voltages and switching (refer to Section 3).<br />

2. Replace the VR cell, VT cell, VR/VT LED or transport.<br />

3. Replace the CCC.<br />

25238801 4-17