<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

REJECT - SPEED<br />

Symptom:<br />

The transport motor speed is not correct.<br />

This is a reject message.<br />

The bill was rejected because the transport motor did not run at a constant speed during validation.<br />

Corrective Action:<br />

1. An object is possibly hung-up or jammed in the track.<br />

2. If bills are frequently rejected for this message, check for tight, binding, or sticky rollers, belts, or flipper.<br />

3. Check that the timing belt tension is not too tight.<br />

4. Check that the +12 VDC supply in the power control center is correct.<br />

5. Check for an intermittent connection in the wiring for the +12 VDC supply, the Red, Black, and Shield wires,<br />

or the White/Black encoder signal wire.<br />

6. Check the motor and timing gear backlash.<br />

7. If all of the preceding checks are OK, replace the transport.<br />

8. If the problem still exists, replace the CCC.<br />

9. Replace the power control center if replacing the CCC does not correct the problem.<br />

If a bill is left in the transport for more than five seconds, the bill changer will go into SELF-CLEAR.<br />

4-14 25238801