Section 4: Troubleshooting<br />
CK CTR TEST SW<br />
Symptom:<br />
The center TEST switch was closed longer than three seconds.<br />
Corrective Action:<br />
The CENTER TEST switch input is (or was) showing an incorrect signal.<br />
In order to prevent spurious payouts, the CCC immediately locks out all TEST switch inputs if it receives an incorrect<br />
signal from one of the TEST switches. Thereafter, the bill changer will still accept bills but will not respond to the TEST<br />
switches.<br />
Press the FUNCTION button. If the message does not reappear, check the wiring to the TEST switches for intermittent<br />
short to Ground. If the wiring is OK, the problem may be an intermittent condition in the CCC.<br />
For a more complete troubleshooting sequence, refer to Troubleshooting Chart 010 at the end of the TEST<br />
SWITCH troubleshooting.<br />
CK RIGHT TEST SW<br />
Symptom:<br />
The right TEST switch was closed longer than three seconds.<br />
Corrective Action:<br />
The RIGHT TEST switch input is (or was) showing an incorrect signal.<br />
In order to prevent spurious payouts, the CCC immediately locks out all TEST switch inputs if it receives an incorrect<br />
signal from one of the TEST switches. Thereafter, the bill changer will still accept bills but will not respond to the TEST<br />
switches.<br />
Press the FUNCTION button. If the message does not reappear, check the wiring to the TEST switches for intermittent<br />
short to Ground. If the wiring is OK, the problem may be an intermittent condition in the CCC.<br />
For a more complete troubleshooting sequence, refer to Troubleshooting Chart 010 at the end of the TEST<br />
SWITCH troubleshooting.<br />
25238801 4-23