<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

BUCKET STAYS ON<br />

Symptom:<br />

A bucket solenoid continued to draw current after it was de-energized.<br />

This is a fault code.<br />

The machine has been shut down because one of the bucket solenoids was energized too long during a normal vend.<br />

Most likely, one of the buckets has an incorrect change load.<br />

Corrective Action:<br />

1. The most likely cause in a faulty computer control center or an intermittent short in the wiring to the buckets.<br />

2. Also, check for a faulty suppression diode on the dispenser.<br />

3. Check the diodes.<br />

4. To restore the machine to service, press the FUNCTION button after correcting the problem.<br />

5. Use a volt-ohmmeter in accordance with Troubleshooting Chart 100 for this error to establish whether on<br />

not it is safe to install a replacement CCC 1 .<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 100 on the next page.<br />

1<br />

Installing a replacement CCC in the machine without determining the cause of the original failure may destroy the<br />

replacement CCC.<br />

4-54 25238801