Section 4: Troubleshooting<br />

EXTRA COIN - R HOP<br />

Symptom:<br />

More than one extra coin was detected passing through the right detector.<br />

Corrective Action:<br />

Since last time bill changer was reset, the bill changer may have dispensed two more coins than it should have during<br />

the replenish cycle. One of the buckets could have an incorrect change load.<br />

1. Most likely, the problem is not electrical. Probable causes are: Faulty hopper motor brakes, or worn parts<br />

on hopper motors.<br />

2. Also, the possible cause could be intermittent connections to the coin detectors, detector LEDs, or wiring.<br />

3. To restore the bill changer to operation, press the FUNCTION button after correcting the problem.<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 050 at the end of this EXTRA<br />

COIN troubleshooting.<br />