<strong>BC</strong>-<strong>3500</strong> Bill and Coin Changer<br />

BUCKET NOT OPEN<br />

Symptom:<br />

A bucket coil did not draw current when it was energized.<br />

This is a fault code.<br />

The machine has been shut down because one of the bucket solenoids failed to energize properly for a normal vend.<br />

An incorrect change load may be in one of the buckets.<br />

Corrective Action:<br />

1. The most likely cause in a faulty computer control center or open connection in the wiring to the bucket.<br />

2. Check R813 on the power supply assembly for possible open circuit conditions.<br />

3. Possible defective drive transistor on the CCC – replace the CCC 1 .<br />

4. To restore the machine to service, press the FUNCTION button after correcting the problem.<br />

For a more complete troubleshooting sequence, refer to Troubleshooting Chart 090 on the next page.<br />

1<br />

Use a volt-ohmmeter in accordance with the troubleshooting chart for this error to establish whether on not it is safe<br />

to install a replacement board. Installing a replacement CCC in the machine without determining the cause of the original<br />

failure may destroy the replacement CCC.<br />

4-52 25238801