PRELIMINARY SPECIFICATION<br />

BT39-I,XL<br />

TRUTH TABLE<br />

SELECT DATA TRANSFER ADDRESS·<br />

DE SC WC MCLK LATCH DIRECTION COMPARISON<br />

L L L X Set 01 Bus .... DO Bus No<br />

L L L X Not set 01 Bus - DO Bus No<br />

L L H X X 01 Bus - DO Bus No<br />

L H X L X 01 Bus - DO Bus No<br />

L H X H X 01 Bus - DO Bus Yes<br />

H X X X X 01 Bus - DO Bus No<br />

NOTES<br />

'When an address comparison is made, the select latch is set if the data on the 01 Bus is within the<br />

manufactured address range of the IV Bus Expander. Otherwise, the select latch is cleared.<br />

FUNCTIONAL BLOCK DIAGRAM<br />

TO OTHER<br />

DATA PATHES<br />

DOX<br />

10F8<br />

DATA PATHES<br />

ENABLE<br />

O-BUS<br />

ENABLE<br />

I-BUS<br />

WC (OUT)<br />

WC(IN)<br />

SC (OUT)<br />

SC (IN)<br />

ME (OUT)<br />

ME (IN)<br />

MCLK (OUT)<br />

MCLK (IN)<br />

NOTES<br />

Selection made during manufacture<br />

X = Don't care<br />

4<br />