ResultCup geometries with screws had been prepared and cup position with screws direction werevery useful. The edge <strong>of</strong> acetabulum and cup edge are well compared <strong>the</strong>n could obtain a bettercup alignment. Screws are said to be safe if <strong>the</strong>y were inserted in upper posterior quadrant.However so long as <strong>the</strong> cluster cup was used, when <strong>the</strong> cup was given 30 degrees anteriorrotation, 25 mm screw was still acceptable using CAT angiography.ConclusionThree dimensional display without goggle was a useful tool to observe preoperative planninginside <strong>the</strong> operation <strong>the</strong>ater.Saturday, October 9, 2010, 16:00-16:50Session B22: Arthroplasty- Getting it Right!Accuracy <strong>of</strong> Cup Center Position, Leg Length, and Offset in Image-FreeHip Navigation System*Fumiaki Inori - Saisekai Nakatsu Hospital - Osaka city, JapanHirotsugu Ohashi - Department <strong>of</strong> Orthopaedic Surgery, Saiseikai Nakatsu Hospital - Osaka,JapanHirotake You - Saiseikai Nakatsu Hospital - Osaka, JapanYoshiaki Okajima - Osaka Saiseikai Nakatsu Hospital - Osaka, JapanKenji Fukunaga - Dept. <strong>of</strong> Orthopaedic Surgery, Osaka City University Graduate School <strong>of</strong>Medicine - Osaka, JapanHideyuki Tashima - Saiseikai Nakatsu Hospital - Osaka, Japan*Email: inorin@flute.ocn.ne.jpIn previous congress <strong>of</strong> <strong>ISTA</strong> in Hawaii, we reported <strong>the</strong> results about accuracy <strong>of</strong> <strong>the</strong> cupcenter position in our image-free navigation system. In <strong>the</strong> new version <strong>of</strong> our navigationsystem, leg elongation and <strong>of</strong>fset change as well as cup center position can be navigated. In thisstudy, we <strong>the</strong>refore investigated <strong>the</strong> accuracy <strong>of</strong> cup center position, leg elongation and <strong>of</strong>fsetchange.Twenty four THA operations were performed with using <strong>the</strong> image-free OrthoPilot THA3.1dysplasia navigation system (B. Braun Aesculap, Tuttlingen, Germany) between August 2009and December 2009 by three experienced surgeons. In this system, cup center height was shownas <strong>the</strong> distance from tear drop, and cup medialization was shown as horizontal distance frominner wall <strong>of</strong> acetabulum. Leg elongation and <strong>of</strong>fset change were navigated by comparing <strong>the</strong>two reference points in femur between registration before neck resection and that after inserting<strong>the</strong> trial implant. After operation, <strong>the</strong> cup angles were measured on CT image, and cup centerposition, leg elongation and <strong>of</strong>fset change were measured on plain radiography. We compared<strong>the</strong>se values that indicated by <strong>the</strong> navigation system to those measured on <strong>the</strong> CT image and <strong>the</strong>plain radiography.The average cup inclination was 37.5 ± 7.0 degree and anteversion was 22.2 ± 4.7 degree. Thefile:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!