11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

and subsequent exposure time to radiation between <strong>the</strong> groups: in <strong>the</strong> research group we usedonly an average <strong>of</strong> 3 seconds <strong>of</strong> staff fluoroscopic exposure (an average <strong>of</strong> 5 fluoroscopicimages) compared to an average <strong>of</strong> 11 seconds <strong>of</strong> exposure (an average <strong>of</strong> 24 fluoroscopicimages). Fur<strong>the</strong>rmore, we have successfully inserted more than 400 pedical screws with lessthan 1mm accuracy from planning, out which only 8 were misplaced. Subsequently we havealso performed 16 biopsies, which were effective as CT based biopsies.The average duration <strong>of</strong> a surgical procedure without <strong>the</strong> use <strong>of</strong> <strong>the</strong> system in 1 level fusion was82 min. With <strong>the</strong> use <strong>of</strong> <strong>the</strong> system <strong>the</strong> average time was 106 min. The operational cost with <strong>the</strong>use <strong>of</strong> <strong>the</strong> system was about 1,000 € more expensive. Fur<strong>the</strong>rmore, <strong>the</strong> use <strong>of</strong> <strong>the</strong> systemrequired performing <strong>of</strong> an additional CT scan with 1 mm slices, which caused an additionalexposure to patient radiation.Results: Robotic assisted spinal surgery is a new and safe approach aiming to dramaticallyshorten <strong>the</strong> duration <strong>of</strong> fluoroscopic exposure <strong>of</strong> <strong>the</strong> staff and surgeon thus reducing <strong>the</strong>exposure to radiogenic dose. This novel procedure, promotes a better accuracy with regard toVertebroplasty, Spinal fusion, insertion <strong>of</strong> Pedical Screws and also for biopsies procedures. Wecontinue to broaden <strong>the</strong> usage <strong>of</strong> <strong>the</strong> robotic assisted device to o<strong>the</strong>r fields <strong>of</strong> spinal surgery andto general orthopaedic surgery. However, we have to resolve some issues such as cost,operation time and less fluoroscopic exposure for <strong>the</strong> patient.Friday, October 8, 2010, 11:10-11:50Session A13: Alternate Bearing Materials in ArthroplastyMedial Neck Femoral Fractures: Our Treatment Alghorithm and <strong>the</strong> Use <strong>of</strong>f.g.l. Memory Shape Stem*Filippo Calderazzi - University <strong>of</strong> Parma, Orthopaedic Unit - Parma, ItalyMichele A. Verdano - University <strong>of</strong> Parma - Parma, ItalyFrancesca de Caro - University <strong>of</strong> Parma - Parma, ItalyAntonio Carolla - University - Parma, ItalyFrancesco Ceccarelli - - Parma,*Email: filippo.calderazzi@tin.itUndisplaced or minimal displaced medial neck femoral fractures are treated with canulatedscrews ei<strong>the</strong>r in young or in elderly patients with good functional capacity, without severecomorbidity and cognitive impairment. We also perform this procedure in patients with verylow daily activities and affected by severe comorbidity, with <strong>the</strong> aim to reduce pain. We reservetotal hip replacement in middle-advanced age, with good level <strong>of</strong> functional activity andadequate bone-stock. We use bipolar hemiarthroplasty in patients that need early mobilizationfor <strong>the</strong> presence <strong>of</strong> comorbidities that could worsen. We prefer cemented bipolarhemiarthroplasty, as it gives an optimal primary stability, without press-fit. We prefer to utilizebipolar hemiarthroplasty with memory shape stem F.G.L. ( Fig.1 ) in high risk patients ( ASAclassification ). In fact <strong>the</strong> use <strong>of</strong> cement prolongs duration <strong>of</strong> surgery and is associated withhigher perioperative mortality from cardiopulmonary complications. This stem in itsmetaphyseal region has 10 tabs, made <strong>of</strong> a Nitinol alloy ( Ni-Ti). The feature <strong>of</strong> this alloy is toenlarge when brought to a certain temperature. When F.G.L. stem is mantained at 4° - 7° Cfile:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!